Description
-
BrandTriconex
-
Model4355X
-
Product NameSafety Communication / Trip Completion Module
-
Country of OriginUnited States
-
HS Code8537101100
-
Dimensions241.3mm*24.4mm*241.8mm
-
Weight1.26 kg (2.78 lb)
-
Operating Temperature−40 °C to +85 °C
-
Storage Temperature−40 °C to +85 °C
-
Humidity5%–95% RH
-
Warranty12 month
-
Product StatusNew and original
Triconex 4355X Product Overview and Technical Specifications
Inputs:
32 differential digital inputs (DC-coupled), 0-5 VDC or -5-+5 VDC range
Input update rate: 10 ms
1*RS-232/485 serial input for local configuration
Outputs:
2 × Ethernet ports (100BASE-TX/1000BASE-T copper; 100BASE-FX/1000BASE-X fiber via SFP)
1 × PROFIBUS DP interface (up to 12 Mbps)
Modbus TCP/IP, Modbus RTU, and Ethernet/IP protocol support
Power Supply:
Voltage: 19.2-28.8 VDC (nominal 24 VDC)
Consumption: 5 W typical
Redundant power input support
Enclosure Rating: IP20 (front)
Certifications: CE, UL, ATEX, IECEx, IEC 61508 SIL 3
Product Advantages:
Unmatched Reliability: TMR design eliminates single points of failure in safety loops
Seamless Integration: Multi-protocol support connects to DCS, SCADA, and third-party systems
Reduced Downtime: Hot-swap and diagnostic tools simplify maintenance
Harsh Environment Durability: Wide temperature and humidity tolerance for industrial settings
Safety Compliance: SIL 3 certification meets global safety standards for process industries
Applications:
Oil & Gas: Emergency shutdown (ESD) systems for refineries, pipelines, and offshore platforms
Power Generation: Boiler protection, turbine overspeed protection, and BMS in thermal power plants
Chemical & Petrochemical: Reactor safety interlocks and process safety monitoring
Pharmaceuticals: Critical process safety and equipment protection
Core Functions:
Safety Communication: Transmits safety-critical data between Triconex SIS and external systems
Trip Execution: Monitors and executes safety trips (ESD, fire & gas) with 10 ms response
System Monitoring: Real-time health monitoring of TMR modules, power supplies, and communication links
Event Logging: Stores up to 512 events with 1 ms resolution for post-incident analysis
Configuration: Local/remote setup via serial or Ethernet ports with user-friendly software
Key Features:
Triple Modular Redundancy (TMR): Fault-tolerant architecture ensures continuous operation despite single-component failures
High-Speed Communication: Gigabit Ethernet and PROFIBUS DP for real-time safety data exchange
Comprehensive Diagnostics: Built-in self-diagnostics with LED indicators and event logging
Hot-Swap Capability: Online replacement without system shutdown
SIL 3 Compliance: Certified for safety-critical applications per IEC 61508