Description
-
BrandDEIF
-
ModelPPU-3
-
Order NumberPPU-3
-
Product NameParalleling & Protection Unit
-
Country of OriginDenmark
-
HS Code8537109100
-
Dimensions144mm × 240mm × 50mm
-
Weight1.8kg
-
Operating Temperature10℃ to 35℃
-
Storage Temperature-20℃ to 38℃
DEIF PPU-3 Technical Parameters
1.Input specification: 3‑phase voltage (100–690V AC) / current (1/5A AC) input, digital dry‑contact input, 8–36V DC auxiliary power input;
2.Output specification: Relay trip/control output, RS485/Modbus TCP/CANbus communication output, LCD display data output;
3.Power supply requirement: 12/24V DC nominal (8–36V DC operating), 11W maximum power consumption; 110–240V AC optional power supply.
Main Functions
1.Generator protection: overload, underload, overvoltage, undervoltage, short circuit, reverse power, and frequency abnormality;
2.Automatic synchronization: precise generator synchronization with other units for parallel operation;
3.Load sharing: proportional load distribution among parallel generators to prevent overload;
4.Real‑time monitoring: three‑phase current, voltage, frequency, power factor, and alarm status display;
5.Remote control: integration with PLC/SCADA for remote monitoring, parameter adjustment, and start/stop control ;
6.Engine control: optional engine interface card for start/stop control and backup monitoring .
Industrial Application Cases
1.Marine industry: Ship and offshore platform generator control, synchronization, and protection systems ;
2.Power generation: Industrial backup generator sets and distributed power plants;
3.Oil and gas: Offshore platform and refinery power management systems;
4.Data centers: UPS and backup generator control systems for critical power reliability;
5.Construction: Temporary power generator sets for construction sites and remote areas.
Product Features
1.Compact all‑in‑one design integrating generator protection, synchronization, and load sharing;
2.Galvanically isolated three‑phase measuring circuits for accurate and safe signal acquisition ;
3.Multiple control modes: load sharing, fixed power, fixed frequency, and droop control ;
4.Separate LCD display (DU‑2) with dimmable backlight for real‑time data and alarm monitoring ;
5. Multi‑protocol communication: RS485, Modbus TCP, CANbus, and J1939 engine bus for system integration;
6.Wide operating temperature (‑40°C to +70°C) and marine certifications (DNV, ABS) for harsh environments ;
7.Built‑in M‑Logic (Micro PLC) function for custom logic configuration via USW‑3 software.