BrandGE
-
ModelDS200SLCCG3ADC
-
Product NameLAN Communications Card
-
Place of OriginUSA
-
HS Code85423190
-
Dimensions245 mm × 185 mm × 80 mm
-
Weight0.53 kg
-
Operating Temperature-20°C ~ +50°C
-
Storage Temperature-40°C ~ +70°C
-
Power Supply24V DC
-
Warranty12 month
-
Product StatusNew and original
Backed by abundant in-stock inventory and nearly 20 years of industry experience, our company stands as a leading player in the industrial control sector.We offer an extensive range of industrial control products covering numerous models. Should you have any other requirements, please feel free to contact us, and we will respond to you promptly.
Our main brand:
1.ABB's module cards, touch screens, controllers, etc., such as PP846 touch screen, IGCT starting with 5SHY, PM starting controller, AI, DO starting input/output module, SP starting Bailey module, etc
2.GE's module card CPUs, such as VMIC starter, IS200, IS215, IS400, IS420 series, etc,
3.Emerson's card components and EPRO probes, Westinghouse 1C series, Honeywell CC series, Schneider 140 series, Envision full series, Bentley 3500 series, Rexroth motors and drives, and Foxboro small modules.
Power Input: 5VDC power fed through the Mark V system backplane connector
Internal Digital Input: Dual-port RAM data signals transmitted from the drive control board
Communication Input: Differential receiving signals RXA and RXB for DLAN/RS422 communication
Peripheral Input: Serial data input sourced from the external alphanumeric keypad
Power Output: On-board regulated power supply serving local circuit components
Communication Output: Differential transmitting signals TXA and TXB for DLAN/RS422 communication
Internal Digital Output: Dual-port RAM data signals sent to the drive control board
Indicator Output: Driving signals for the on-board status LED indicators
Peripheral Interface I/O: Bidirectional serial communication channel connecting to the external keypad
Memory I/O: Bidirectional data bus interfaced with U6 and U7 EPROM modules
External P5 Connector Signal Definition
+5VDC Input
DCOM (Digital Common Ground)
TXA, TXB – Differential Transmit Outputs
RXA, RXB – Differential Receive Inputs

Pre-Commissioning Inspection (Power OFF Status)
Wear a grounded ESD wrist strap before handling the module. Inspect the PCB for physical damage including scratches, burnt components, bent pins and corrosion.
Verify U6/U7 EPROM firmware matches the turbine control configuration and confirm JP15 jumper setting (isolated/non-isolated DLAN) per site drawings.
Install the card vertically into the designated backplane slot and fasten the mounting screws securely.
Wire the shielded twisted-pair ARCPL cable to the P5 connector for TXA, TXB, RXA, RXB and DCOM. Install an external 16-key keypad if local diagnosis is required.
Check proper installation of DLAN bus terminating resistors at both cable ends and use a multimeter to rule out short circuits on all bus and communication wiring.
Power-Up and Initial Boot Test
Complete final wiring inspection and ensure all connectors are fully seated before closing the cabinet door.
Power on the Mark V chassis gradually. A steady onboard LED indicates normal 5VDC backplane power.
Wait 10–30 seconds for LCP bootup from EPROM modules. Check and record any abnormal or constant red fault LED status during initialization.
Basic Communication Verification
Access the diagnostic menu via the external keypad and confirm the correct DLAN node address is assigned.
Verify stable bidirectional dual-port RAM communication between the SLCC card and drive control board, as well as normal operating status of all DLAN differential Tx/Rx signals.
Clear historical faults and monitor for new communication error codes.
Parameter Configuration
Modify LAN node address and other network parameters only under full system shutdown, then save all configuration changes.
Perform a chassis power cycle to confirm effective and stable parameter retention after reboot.
Online Functional Test
Keep the system in idle status and continuously monitor communication buffer data for a minimum of 30 minutes.
Check for recurring faults such as communication timeout, parity error and DLAN bus conflicts. Verify consistent data transmission among all DLAN nodes and stable keypad communication.
Fault Simulation & Stability Check (Offline Unit Only)
Disconnect and reconnect the P5 cable to test link recovery capability. Confirm only standard communication loss alarms trigger without turbine trips.
Restore wiring and verify automatic DLAN link recovery.
Post-Commissioning Documentation
Record EPROM firmware version, JP15 mode and DLAN node address. Save all diagnostic fault records.
Confirm zero persistent communication errors during testing and file all records for future maintenance reference.
Important Notes
Hot swapping is strictly prohibited. Isolated and non-isolated nodes cannot coexist on one DLAN bus.
Resolve boot or communication faults by re-seating EPROM cartridges and inspecting wiring first.
Refer to GE official manual GEI-100162 for full technical specifications.

Frequently Asked Questions (FAQ)
1.How fast will you reply to my inquiry?
We process all inquiries efficiently and will respond promptly once we receive your message.
2.Do you carry large inventory of industrial control parts?
We maintain massive ready stock of mainstream automation spare parts to shorten lead times.
3.Can you source discontinued or obsolete PLC & DCS modules?
Absolutely.
We specialize in sourcing hard-to-find, obsolete and out-of-production industrial control components.
4.Do you inspect goods before shipment?
Every product undergoes thorough inspection before packing and dispatch.
5.Can you ship orders worldwide?
We provide global shipping with flexible logistics for urgent and regular orders.
6.What payment methods are available?
We accept multiple secure payment options. Please contact our sales team for detailed terms.