Description
-
BrandABB
-
ModelPP886
-
Product NameIndustrial Touchscreen Operator Panel for Freelance DCS
-
Place of OriginSweden
-
HS Code85285910
-
Dimensions410mm × 286mm × 73mm
-
Weight3.85kg
-
Operating Temperature-10℃ to +60℃
-
Storage Temperature-20℃ to +70℃
-
Part Number3BSE092980R1
-
Warranty12 month
-
Product StatusNew and original
Backed by abundant in-stock inventory and nearly 20 years of industry experience, our company stands as a leading player in the industrial control sector.We offer an extensive range of industrial control products covering numerous models. Should you have any other requirements, please feel free to contact us, and we will respond to you promptly.
Our main brand:
1.ABB's module cards, touch screens, controllers, etc., such as PP846 touch screen, IGCT starting with 5SHY, PM starting controller, AI, DO starting input/output module, SP starting Bailey module, etc
2.GE's module card CPUs, such as VMIC starter, IS200, IS215, IS400, IS420 series, etc,
3.Emerson's card components and EPRO probes, Westinghouse 1C series, Honeywell CC series, Schneider 140 series, Envision full series, Bentley 3500 series, Rexroth motors and drives, and Foxboro small modules.
1. Input Power Voltage Specification
Rated Nominal Input Voltage: 24 VDC
Stable Operating Voltage Range: 18 VDC ~ 32 VDC (24VDC ±25% wide tolerance range)
Permitted Instantaneous Overvoltage Limit: 36 VDC (short-time surge withstand)
Reverse Polarity Protection: Built-in anti-reverse wiring protection circuit, no damage caused by temporary positive-negative reversal of power supply
Working power supply type: Pure DC power supply, industrial regulated 24VDC power supply is recommended
2. Operating Current Parameters
Typical Quiescent Operating Current: 1.3 A (@ standard 24VDC normal running state)
Maximum Continuous Operating Current: 1.5 A
Peak Inrush Current (power-on instant): 1.8 A, duration less than 100ms
Standby Low-load Current: 0.7 A (screen dimming idle mode)
USB Port Output Current: Dual USB2.0 interfaces, single-channel maximum output current 500mA
3. Power Consumption Matching Current-Voltage
Typical Normal Operating Power Consumption: 31.2 W
Maximum Full-load Power Consumption: 43 W
Theoretical Max Current Calculation at rated voltage: 43W÷24V≈1.79A, consistent with measured peak limit
4. Additional Electrical Protection & Supplementary Description
Integrated overvoltage, undervoltage, overcurrent and short-circuit protection inside the module;
Voltage fluctuation within 18~32VDC will not trigger abnormal restart or screen flicker;
Long-term operation under 20~28VDC voltage interval can extend the service life of the touch screen;
The current fluctuation is mainly affected by screen brightness, USB external load and data communication frequency.
1. Pre-installation Preparation
Check overall hardware integrity; operating environment: -10℃~+60℃, humidity ≤85% non-condensing.
Use anti-static protection during wiring; input rated 24VDC (18~32VDC allowable range).
Cabinet opening size: 394mm×270mm.
2. Installation
Mount the panel into cabinet opening, fasten 4 rear fixtures evenly.
Front face IP65, rear IP20; reserve ≥3cm rear clearance for heat dissipation.
3. Wiring
3.1 Power Wiring
Connect 24VDC correctly, reverse polarity protection available; use 1.0~1.5mm² wires; max transient voltage 36VDC; reliable grounding required.
3.2 Communication Wiring
Shielded cables for Ethernet, RS232/RS422; USB ports for program download and storage expansion; keep signal cables away from high-power cables.
4. Offline Programming
Configure projects with Panel Builder 800 V6.2 and above; design HMI screens, bind variables, set communication parameters.
Verify via offline simulation, then download projects to local SSD via Ethernet or USB.
5. Power-on & Initial Setup
Power on after short-circuit inspection; automatic 20~40s self-check.
Calibrate touch screen if offset; set system time, language, brightness and administrator passwords; check communication status.
6. Daily Operation
Tap buttons for equipment control, slide to switch pages, long press blank area for authorized system menu access.
Check real-time data, view & reset alarms, query historical trends, modify protected parameters, back up data to USB flash drive.
7. Maintenance
Monthly: clean screen, check wiring and communication, back up programs.
Semi-annually: clean heat sink, recalibrate touch screen, test alarms and power supply.
Annually: official firmware upgrade, full function inspection, sealing check.
Replace RTC button battery every 2~3 years with power disconnected.
8. Troubleshooting
No power supply: check voltage, wiring and short-circuit faults.
Touch failure: recalibrate or clean screen; replace hardware for aging issues.
Communication disconnection: check cables and IP settings, restart devices.
Screen flicker: stabilize power supply and reduce electromagnetic interference.
Missing programs: restore backup files via USB or Ethernet re-download.
9. Safety Rules
Cut power off before maintenance; avoid sharp scratches and heavy extrusion on screen.
Keep flammable & corrosive substances away; forbid unauthorized modification of system files.
Seal and store the device dryly during long downtime.

Frequently Asked Questions (FAQ)
1.How fast will you reply to my inquiry?
We process all inquiries efficiently and will respond promptly once we receive your message.
2.Do you carry large inventory of industrial control parts?
We maintain massive ready stock of mainstream automation spare parts to shorten lead times.
3.Can you source discontinued or obsolete PLC & DCS modules?
Absolutely.
We specialize in sourcing hard-to-find, obsolete and out-of-production industrial control components.
4.Do you inspect goods before shipment?
Every product undergoes thorough inspection before packing and dispatch.
5.Can you ship orders worldwide?
We provide global shipping with flexible logistics for urgent and regular orders.
6.What payment methods are available?
We accept multiple secure payment options. Please contact our sales team for detailed terms