IC3600STKD1 GE Interface Module new and original

The GE IC3600STKD1 is a plug-in temperature control printed circuit board for the Speedtronic Mark I / Mark II gas turbine control system, conditioning and comparing exhaust thermocouple temperature signals (TXA / OTA / OTB) for temperature control and over-temperature protection, built on an FR4 PCB with gold-plated edge-connector pins, trimming potentiometers, MOVs and discrete analogue circuitry for rack/backplane mounting.

Whatsapp: +86 18059281365
WeChat: +86 19120578390
Tel: +8619120578390
E-mail: Cathyyou401@gmail.com

Description

Technical Specifications
  • Brand
    GE
  • Model
    IC3600STKD1
  • Product Name
    Timing and Trigger Control Board
  • Place of Origin
    United States
  • Customs HS Code
    85371011
  • Power Supply
    24 V DC
  • Dimensions
    120 mm × 35 mm × 110 mm
  • Weight
    0.32 kg
  • Operating Temperature
    -20 ℃ to +60 ℃
  • Storage Temperature
    -40 ℃ to +85 ℃
  • Warranty
    1year
  • Product Status
    new and original

GE IC3600STKD1 Input & Output, Compatible Systems-Software, Voltage & Current

Input and Output

Thermocouple Analog Inputs: Multi-channel inputs designed for millivolt-range thermocouple signals sourced from turbine exhaust, combustion chamber and bearing temperature sensors.

On-board Signal Conditioning: Amplifies and filters faint raw millivolt thermocouple signals for reliable processing.

Processed Analog Output: Converted temperature analog signals transmitted to the main control backplane.

Discrete Logic Output: Threshold-based on-off trigger signal for overtemperature alarm and safety protection interlock functions.

Interface Type: 50-pin edge connector for backplane connection; field devices are not directly wired to this board.

Compatible Systems

GE Speedtronic Mark-I gas turbine control system

GE Speedtronic Mark-II gas turbine control system

Matches original rack backplane, serves as a direct drop-in replacement for legacy temperature conditioning circuit boards.

Note: This is an older analog circuit board and is incompatible with digital turbine control platforms including Mark-V, Mark-VI and Mark-VIe.

Compatible Software

Calibration is completed through on-board hardware potentiometers; no modern PC-based configuration software is supported.

Parameter Setting: Temperature threshold and offset calibration are performed manually via potentiometers mounted on the circuit board.

No specialized PC programming utilities; operational status is monitored locally from the original turbine control panel display.

Voltage and Current

Module Power Supply: 24 V DC power fed through the system backplane.

Power Consumption: Low-power analog circuitry with typical board current draw less than 150 mA.

Input Signal Level: Thermocouple millivolt signal, typical measuring range 0-50 mV.

Output Signal Level: Conditioned low-level analog voltage; discrete logic outputs adopt TTL-compatible levels for internal rack logic circuits.

No high-current field-side driving capability; all outputs are intended exclusively for internal control-rack connections.

 IC3600STKD1.jpg


Application Cases of GE IC3600STKD1

Coal-fired Power Plant Gas-Turbine Retrofit Mounted within GE Speedtronic Mark-I / Mark-II control cabinets, this module conditions thermocouple signals from turbine exhaust, combustion chambers and bearing positions. Processed temperature values are forwarded to the main control logic, enabling fuel cut-back or safe unit shutdown upon overtemperature events. It is extensively applied for spare-part replacement and service-life extension maintenance on legacy gas-turbine assets.

Combined-Cycle Power Plant Steam Turbine Monitoring Acting as a temperature signal conditioning card for older steam-turbine control systems, it gathers multi-point temperature measurements from turbine casings, rotors and exhaust ducts. Delivers analog temperature feedback for startup ramps, load modulation and thermal-stress supervision, mitigating equipment damage caused by thermal cycling during unit start-stop sequences.

On-Site Oil & Gas Compressor Station Installed on gas-turbine-powered compressor packages at natural-gas transmission facilities. It tracks exhaust gas and bearing-metal temperatures of the driving turbine and participates in overtemperature interlock protection. Continuous safe compressor operation is secured under variable gas-flow conditions while preserving the original control framework without extensive system overhauls.

Industrial Waste-Heat Power Generation Deployed on Mark-II-based waste-heat gas-turbine control systems. It handles multiple thermocouple inputs originating from waste-heat boilers and turbine exhausts. Closed-loop temperature control for flue gas and fuel gas is supported to stabilize power generation amid fluctuating waste-heat supply.

Offshore Platform Turbine Auxiliary Control Utilized for legacy gas-turbine generator units on offshore oil-and-gas platforms. Designed to withstand harsh operating conditions including high humidity and salt-fog corrosion. It precisely captures vital thermal parameters and works with safety interlock logic to avoid turbine overheating failures. Primarily used for MRO spare-part swap-outs in existing offshore control cabinets.

Legacy System MRO and Spare-Part Renewal Projects Suitable for worldwide in-service Mark-I / Mark-II turbine control installations. IC3600STKD1 serves as a drop-in replacement when original temperature-sensing boards degrade or fail. Existing control logic remains untouched, lowering renovation expenditure and shortening unit downtime.

IC3600STKD1 (2).jpg

DS200PTBAG1BBA
DS200TDAH1BHD
DS200TCRAG1ACC
DS200DTRAG1AAA
DS200DTBBG1ABB
DS200SDCCG4AFD
DS200TCDAG1BDB
IS220PTURH1B
C60G01HCHF8FH6PM8FP6PU6PWXX
DS200TCQCG1BHF

Related Products

Quick Navigation
Online Message
If you have any questions, you can leave us a message and we will contact you within 24 hours!

Copyright © 2026 MASSIVE INTERNATIONAL COMMERCE PTE. LTD.

  • Home
  • Mess
  • Tel
  • Top
  • Online Message
    Send Mail