DEM401 SAM Digital Input Module in stock

The SAM Electronics (Lyngsoe Marine) DEM401 is a marine-grade 32-channel isolated digital input module for Gamma/NAVIS automation racks, accepting dry-contact or 24 VDC wet-contact signals (logic high 18–30 VDC) with per-channel optocoupler isolation ≥1500 VAC, ≤1 ms response, 24 VDC ±20% supply at ≤5 W, IP20 cabinet mounting, −15 °C to +70 °C operation and DNV/GL/LR/ABS class approval . Housed in a ~225 × 115 × 35 mm, ~0.5 kg plug-in card with per-channel and fault LEDs, it feeds discrete switch/sensor status to engine-room alarm, monitoring and engine control systems .

Whatsapp: +86 18059281365
WeChat: +86 19120578390
Tel: +8619120578390
E-mail: Cathyyou401@gmail.com

Description

Technical Specifications
  • Brand
    SAM
  • Model
    DEM401
  • Product Name
    Digital Input Module
  • Place of Origin
    Denmark
  • Customs HS Code
    85389000
  • Power Supply
    24V DC
  • Dimensions
    120mm × 90mm × 40mm
  • Weight
    0.51kg
  • Operating Temperature
    -20℃ ~ +70℃
  • Storage Temperature
    -25℃ ~ +75℃
  • Warranty
    12 month
  • Product Status
    new brand

DEM401 SAM Digital Input Module (Sam Electronics / Lyngsoe Marine)

Input & Output

Inputs: Galvanically-isolated 24 V DC binary digital inputs, purpose-built for marine-grade digital signal acquisition. Outputs: Internal system bus interface for connection to SAM marine automation platform; no physical analog field output terminals available.

Supported Communication Protocols

SAM proprietary internal system bus; Modbus RTU via RS485 interface; TCP/IP and Modbus TCP over Ethernet network.

Compatible Systems

Native SAM / Lyngsoe Marine integrated marine automation and alarm monitoring systems; third-party PLC, SCADA and HMI hardware supporting Modbus RTU / Modbus TCP; general-purpose vessel monitoring and control systems.

Compatible Software

Original SAM proprietary configuration and monitoring software; standard Modbus-supported SCADA suites; HMI configuration tools; Modbus diagnostic polling utilities for commissioning and field troubleshooting.

DEM401 (2).jpg

DEM401 SAM Digital Input Module Operation Procedures (Sam Electronics / Lyngsoe Marine)

Pre-installation Safety Verification Ensure complete de-energization of the power circuit. Inspect field-cable insulation resistance and rule out potential short-circuit hazards. Confirm installation surroundings satisfy marine-grade EMC and ambient temperature specifications.

Hardware Installation Secure the DEM401 module onto the DIN rail within the marine control cabinet. Fasten the module reliably and maintain adequate clearance for thermal dissipation.

Terminal Wiring Connect the 24 V DC power supply to corresponding power terminals with correct polarity. Terminate 24 V DC binary field signals to galvanically-isolated digital input terminals. Attach communication cables to RS485 or Ethernet interfaces for SAM internal bus and Modbus communications. Fully torque all terminal screws and implement proper cable strain-relief measures.

Pre-power-on Hardware Verification Re-examine all wiring to eliminate reversed polarity, short-circuits and loose connections. Validate that bus address and DIP-switch configurations align with overall system design specifications.

Power-on and Initial Health Check Supply 24 V DC power to the module. Monitor LED status indicators to confirm stable power input and absence of hardware failures. Allow sufficient time for the module to finish built-in self-diagnosis routines.

Software Parameter Configuration Start the native SAM configuration software or compatible Modbus setup utility. Set the module communication address, configure input-channel attributes and signal trigger thresholds. Download compiled parameters to the DEM401 unit and archive project configuration files.

Signal and Communication Commissioning Actuate field dry-contact inputs to test every digital channel. Confirm real-time signal states are accurately transmitted to the SAM automation platform or Modbus master station. Validate reliable data exchange over the internal system bus, Modbus RTU and Modbus TCP links.

Troubleshooting and Fault Handling Evaluate LED alarm indications for module-level malfunctions. Retrieve fault register data via SAM diagnostic utilities or Modbus polling tools. Isolate defective input channels or faulty communication segments for targeted repair work.

System Validation and Commissioning Hand-over Carry out extended operational tests for marine alarm and monitoring functionalities. Document all test results, back-up module configuration files and finalize full commissioning records.

Module Decommissioning Cut off power supply prior to disassembly. Disconnect field signal conductors and communication cables sequentially. Release the DIN-rail locking mechanism and remove the physical module.

DEM401.jpg

UKB-3-35E
MFT-06
H1111.0204
HC-RFS353K
85UVF1‑1CEX
SH31004P12A2000
PW482‑50 S2
PW484-50 S1
AAR181-S50 S2
AAI143-H50 S1
85UVF1-1QD
CCM10