ASEM HMI30 Interface Touch Panel new brand

The ASEM HMI30 is an ARM-based industrial operator panel built around an NXP i.MX535 ARM Cortex-A8 1 GHz CPU running Windows Embedded Compact 7 Pro, offered with 5.7″–15.6″ LED-backlight TFT LCDs (640×480 to 1366×768) and 4-/5-wire resistive or projective-capacitive touch on an aluminium or TrueFlat aluminium front panel rated IP65/IP66 front, UL Type 4X (indoor).

Whatsapp: +86 18059281365
WeChat: +86 19120578390
Tel: +8619120578390
E-mail: Cathyyou401@gmail.com

Description

Technical Specifications
  • Brand
    ASEM
  • Model
    HMI30
  • Product Name
    Industrial Human‑Machine Interface Touch Panel
  • Dimensions
    5.7‑inch
  • Weight
    0.90 kg
  • Place of Origin
    Italy
  • HS Code
    8537109000
  • Operating Temperature
    0 °C to +50 °C
  • Storage Temperature
    ‑20 °C to +60 °C
  • Power Supply
    0.75 A
  • Warranty
    12 month
  • Status
    new brand

ASEM HMI30 Key Features

Hardware Specifications

Processor: ARM Cortex-A8 (i.MX535) 1 GHz with integrated graphics GPU

Memory configuration: 1 GB DDR3 RAM; 256 MB NAND-Flash for operating-system runtime; 4 GB eMMC for HMI project and historical-data storage

Display options: 5.7”, 7”, 8.4”, 10.4”, 12.1”, 15.0”, 15.6-inch TFT-LCD panels, available in 4:3 standard or wide-screen formats, LED backlight, maximum 16.7-million-colour display

Touch technology: standard resistive touch; HMI30-TF true-flat resistive touch; HMI30-TFC projected capacitive touch

Mechanical construction: full-aluminium or true-flat aluminium front panel; front-panel protection rating IP66, indoor NEMA 4X compliance

On-board interfaces:

 Dual 10/100 Mbps Ethernet ports; LAN-1 supports IEEE1588 precise time-synchronization, LAN-2 dedicated for ASEM Ubiquity remote-service connection

 1 DB15 serial port with software-selectable RS232/422/485, compatible with Siemens MPI at baud-rate up to 187.5 kbit/s

 2 rear-mounted USB2.0 Type-A host ports

 Push-push-type external SD/SDHC card slot for data backup and event-log export

Power input: 18-36 VDC DC supply, built-in reverse-polarity and over-voltage protection; optional MicroUPS super-capacitor backup providing 500 ms hold-up time for data preservation during brief power drops

Environmental conditions: operating temperature 0 °C ~ +50 °C; storage temperature -20 °C ~ +60 °C; designed for panel-mount installation

Software & Operating System

Embedded OS: Windows Embedded Compact 7 Pro

HMI runtime environment: Premium-HMI 3 / 4 Basic and Advanced versions, supporting object-oriented project development

Remote-maintenance tool: ASEM UBIQUITY, enabling remote access, online diagnosis and equipment maintenance via Ethernet network

Core application functions: alarm handling, historical data logging, recipe management, real-time and historical trend curves, multi-level user-access permission control, CSV-format data import and export

Communication Performance

Native support for widely-used industrial protocols including MPI, Modbus-RTU, Modbus-TCP and OPC-DA, together with abundant driver libraries for various mainstream PLC brands

IEEE1588 precision time-synchronization function on primary Ethernet port, ensuring unified timestamp across the whole automation system

Certifications & Typical Applications

Approvals: cULus, CE, indoor NEMA 4X

Target industries: machinery manufacturing, packaging equipment, process automation and water-treatment facilities

ASEM HMI30 .jpg

ASEM HMI30 Wiring Instructions

1. Power Supply Wiring

Equipped with rear industrial round power connector, supporting 18–36 VDC wide-range input (rated 24 VDC standard operation).

Pin definition: DC 24V positive, DC 0V negative, PE protective earth terminal.

Wiring requirements: Strictly distinguish positive and negative poles. Built-in reverse polarity and over-voltage protection prevents accidental power damage.

The PE protective earth must be firmly connected to the cabinet grounding bar; PE is isolated from signal ground and cannot be connected mutually.

Optional Micro-UPS supercapacitor module provides 500ms power hold-up time to ensure data saving during instantaneous power failure, supporting plug-and-play installation without additional wiring.

Recommended wire gauge: 0.75–1.5 mm² shielded power cable.

2. Ethernet Wiring (LAN1 / LAN2, RJ45 Interface)

LAN1: Main industrial network port, supports IEEE1588 precise time synchronization, connected to PLC and DCS system switches.

LAN2: Independent dedicated port for ASEM Ubiquity remote diagnosis and maintenance services, connected to remote access network.

Cable standard: Industrial CAT5e / CAT6 shielded twisted-pair cable.

Wiring note: The two Ethernet ports operate independently without built-in bridging. Avoid arbitrary interconnection of LAN1 and LAN2 through external switches without network planning.

3. Serial Port COM1 (DB15 Male Interface)

Software-selectable communication modes: RS232, RS422, RS485 and Siemens MPI; hardware wiring must match the software configuration mode.

RS232 Point-to-Point Wiring

HMI TX ↔ PLC RXD

HMI RX ↔ PLC TXD

HMI GND ↔ PLC Signal GND

RTS/CTS hardware handshake is only required for specific scenarios; keep unconnected for conventional Modbus-RTU communication.

RS485 Two-Wire Multi-Drop Wiring (Modbus-RTU / Siemens MPI)

HMI Data+ ↔ PLC A / D+

HMI Data- ↔ PLC B / D-

Connect signal ground between HMI and all slave devices uniformly.

Install 120 Ω terminal resistors at both ends of the bus; adopt daisy-chain topology and prohibit star branch wiring.

Supports Siemens MPI protocol with maximum baud rate of 187.5 kbit/s.

RS422 Four-Wire Full-Duplex Wiring

HMI TX+ ↔ Remote Device RX+

HMI TX- ↔ Remote Device RX-

HMI RX+ ↔ Remote Device TX+

HMI RX- ↔ Remote Device TX-

Implement common signal ground connection for all devices.

4. USB Interfaces (USB1 / USB2, Rear Type-A Host)

Used for connecting peripheral devices such as USB mouse and keyboard, and supporting program downloading and log export via U disk.

Single-port maximum output current: 500 mA; high-power USB devices are prohibited.

Plug-and-play design with no additional wiring required.

5. SD/SDHC Card Slot

Rear push-pull card slot, no wiring needed.

Applied for program recovery, recipe backup and alarm log storage, compatible with SD/SDHC cards up to 32GB.

6. Grounding and EMC Installation Specifications

The front-panel IP66 protection level is only valid with standard panel installation and intact sealing gaskets.

Signal cables adopt single-end grounding at the cabinet grounding bar; double-end grounding is forbidden to avoid ground loop interference.

Keep power cables and signal cables separated with a spacing of no less than 20 mm to reduce electromagnetic interference.

Reliable PE grounding is mandatory; floating grounding installation is prohibited.

7. General Wiring Precautions

Complete all wiring work before powering on the device; hot plugging of DB15 serial port is forbidden during operation.

The serial communication mode is software-defined; mismatched wiring and configuration will cause communication failure.

Strictly follow official cutting size for panel installation; protect the gasket to ensure IP66 protection performance.

USB and SD card interfaces support hot swapping; power supply and serial ports do not support hot plugging.

8. Typical Application Wiring Topology

Standard automatic system: LAN1 connects to PLC switch, COM1 RS485 connects to Modbus-RTU field equipment, LAN2 is reserved for Ubiquity remote access.

Siemens MPI communication: Use dedicated DB15-MPI cable to directly connect S7-300/400 series PLC, and set 187.5 kbit/s baud rate in the HMI project software.

ASEM HMI30.jpg

UKB-3-35E
MFT-06
H1111.0204
HC-RFS353K
85UVF1‑1CEX
SH31004P12A2000
PW482‑50 S2
PW484-50 S1
AAR181-S50 S2
AAI143-H50 S1
85UVF1-1QD
CCM10

Related Products